Noise Monitor and Decibel Logger

Noise Monitor & Logger

—dBFS · A-weightedMicrophone off

Up to 12 hours / 43,200 log rows. Browsers and devices may suspend background audio or lock-screen processing; interrupted periods are flagged, not filled with invented readings. Export before leaving this page.

Minimum displayed level—
Maximum displayed level—
Estimated energy average / Leq—
Digital sample peak · dBFS—
Measured seconds—
Clipping frames—

Uncalibrated: relative digital levels, not sound pressure level. Nothing is recorded or uploaded by measurement tools.

Numeric measurements are available above and in export.
Microphone, weighting and calibration

Match a calibrated reference meter during steady sound at the same position and weighting. A saved offset is specific to microphone, sample rate and weighting; one offset cannot correct frequency-response or gain-control errors. Settings change starts a fresh session. No calibration makes a browser instrument certified.

Most recent 100 log entries · complete data in CSV
Time · sLevelUnitEvent
No measurements yet.
Ready when you are.

Related tools

Use the noise monitor and logger when you need a sequence of sound-level observations rather than one changing number. It captures microphone levels, adds timestamped log rows and marks readings that meet your selected event threshold. At the end, download the CSV to compare periods, identify changes and keep the conditions of the session alongside the measurements.

The starting unit is relative digital dBFS. Reference calibration can change the display to an estimated acoustic level, but this browser logger is not a certified noise dosimeter or a guaranteed unattended monitoring service. For a quick check without a log, use the online decibel meter.

Set up a useful noise logging session

  1. Place the microphone at a fixed location relevant to the comparison. Note the input device, position and surrounding activity.
  2. Choose weighting and response in the microphone settings. Calibrate only if you have a valid reference or known offset.
  3. Enter an event threshold in the displayed unit. A negative dBFS threshold is appropriate for a relative digital signal; a positive acoustic threshold needs a corresponding calibrated estimate.
  4. Choose a log interval of 1, 5 or 10 seconds and an automatic stop duration, up to 12 hours.
  5. Start the microphone and check that measured seconds and log rows advance. Stop when the comparison is complete and export before leaving.

The visible table shows the most recent 100 entries. That is a display limit, not the complete session. The CSV contains the collected log, subject to the maximum of 43,200 rows. A longer interval reduces the number of exported observations; it does not turn an unreliable microphone into a more accurate instrument.

Understand what each logged row represents

A row includes measured elapsed seconds, a timestamp, the current displayed level, its unit and event or interruption information. The timestamp helps relate an observation to something that happened, while measured time describes the audio actually processed. They answer different questions when delivery is interrupted.

The logged level is the current smoothed reading at that logging point. It is not a separate Leq calculation for every entire interval. The session energy average uses the captured audio across measured time. Therefore, averaging the visible CSV level column arithmetically will not reproduce the session’s energy average.

For example, if a fan changes setting between two five-second log points, the table helps locate the change approximately. It does not prove the exact starting instant or capture every brief peak between rows. Keep an independent note of when you made the adjustment if timing is important.

Threshold flags are observations, not identified events

A threshold flag indicates that the logged level reached or exceeded your chosen threshold. It does not identify a voice, appliance, animal or particular neighbour. Several successive flagged rows can belong to one sustained sound. Conversely, a short sound between logging points may not appear as a flagged row.

Use a threshold suited to your question. First observe the ordinary background, then choose a level that distinguishes the change you want to inspect. Keep the threshold and unit in the exported record. Do not describe a user-selected threshold as a published limit or evidence of a legal violation.

To investigate the character of a sound, take a separate look with the frequency analyzer. Its spectrum can reveal frequency components, but cannot identify their physical source with certainty either.

Keep weighting, calibration and position consistent

A, C and Z weighting count frequency content differently. Fast and Slow response smooth changes over different time scales. Changing either can alter the displayed trace even if the environment has not changed. Compare like with like and begin a fresh session when the setup changes.

Calibration matches the digital input to a supplied reference. A saved offset is specific to the microphone, sample rate and weighting; it does not correct every frequency-response or gain error. Uncalibrated results remain useful for controlled relative comparisons, but should not be reported as measured room dBA.

A sensible comparison might use two similar occupied periods at the same desk, once with a window open and once closed. Record traffic or other differences that could explain a change. Comparing a silent morning with a busy afternoon would confound the window setting with a different sound environment.

Background tabs and missing time

Ordinarily, leaving the tool hidden stops its microphone activity. The logger offers an explicit Keep logging when this tab is hidden option, but this is best effort. A browser or operating system may suspend audio, reduce background activity or stop processing when the device locks or sleeps.

Interrupted delivery is flagged rather than filled with invented levels. Measured seconds may consequently differ from the time you expected the browser to have been running. Review both the timestamps and measured duration before interpreting a long session. Do a short trial under your intended device conditions before relying on a longer observation.

There is no cloud dashboard, automatic email alert or permanent session archive. Download the data yourself. A 12-hour setting is a software bound, not proof of 12 hours of uninterrupted measurement on your hardware.

Choose the right follow-up

The background noise test is more convenient for a short, quiet baseline. The classroom noise monitor provides sustained-threshold visual feedback for an activity. Those tools serve different needs from maintaining a timestamped log.

If your question concerns daily exposure, collect suitable acoustic measurements and activity durations before using the noise exposure calculator. A browser log of relative dBFS does not establish personal exposure, and a desktop microphone does not automatically represent the sound at someone’s ear.

Frequently asked questions

Does this noise logger record conversations?

The logger processes microphone samples locally to calculate levels. It does not create a playable recording or upload audio. Exported rows contain measurements, not a transcript or sound recording.

Why can I see only 100 rows?

The table keeps the latest 100 rows visible so a long session does not overload the page. Download CSV to obtain the collected session rows up to the stated limit.

Can I leave it running overnight with the screen locked?

Continuous lock-screen operation is not guaranteed. The hidden-tab option cannot override device suspension. Review a short trial and its measured duration; use dedicated logging equipment when uninterrupted monitoring is essential.

Does an event flag mean the room exceeded a safe level?

No. It compares a reading with your chosen threshold in the displayed unit. It is not a risk assessment, exposure dose or compliance decision.

Can I recover a log after closing the page?

The tool does not maintain a persistent results library. Export the CSV before closing, resetting or replacing the session. Explicitly saved numeric calibration is separate from the log.

Scroll to Top