Microphone Polar Patterns: Cardioid, Omni and Room Noise

A microphone polar pattern describes how its response changes with the direction of incoming sound. Cardioid, omnidirectional and figure-eight are familiar pattern names. They describe directionality, not whether a microphone is dynamic or condenser, whether it is powered by USB, or whether it automatically removes room noise.

Read the pattern with its frequency and orientation. A microphone that rejects a sound well from one direction at one frequency may behave differently elsewhere. One attractive diagram is not a complete map of every real recording condition.

What a polar plot represents

A typical plot puts the microphone at the center and marks angles around it. Zero degrees commonly represents the front, but verify the manufacturer’s convention and the microphone’s physical front. Relative response is shown as sound arrives from those directions under specified conditions.

Shure’s directionality guidance emphasizes both off-axis behavior and consistency across frequency. The plot is a response description, not a map of a sharply bounded area beyond which a microphone hears nothing.

Common pattern families

Broad idealized pattern descriptions; real response depends on the model and frequency
PatternUseful starting descriptionImportant limitation
OmnidirectionalReceives from around the microphoneReal response need not be identical at every angle and frequency
CardioidFavors the front with reduced rear responseOff-axis sound is reduced, not universally eliminated
Supercardioid or hypercardioidNarrower forward response with a rear lobeDirectly behind is not necessarily the best rejection direction
Figure-eightFront and rear sensitivity with side rejectionRear sound remains part of the capture

Choose according to the actual source and unwanted sound positions. A narrower front label is not automatically better for a moving speaker or a group of people.

Directionality and transducer type are separate

A moving-coil microphone can have a directional or an omnidirectional design. Condenser microphones also come in several patterns. The electrical or mechanical conversion principle does not by itself identify the directional response.

For a practical check, the microphone test can help you compare the received input as the setup changes. It does not determine a certified polar pattern from one recording or turn an ordinary single-channel microphone into a different physical capsule design.

A simple mathematical illustration

Consider an explicitly ideal amplitude model A(θ) = (1 + cos θ)/2. It produces a familiar cardioid-shaped angular relationship. At zero degrees, A is 1; at ninety degrees, A is 0.5; at 180 degrees, it is zero.

The ninety-degree relative level is 20 log10(0.5), about −6.02 dB. The zero at the rear is a mathematical null in this chosen model, not a claim of infinite rejection in a real microphone. This example is neither a measured product plot nor a room-noise reduction rating.

Frequency changes the picture

A manufacturer may publish several traces for different frequencies. Compare them instead of assuming a one-kilohertz curve describes bass, midrange and treble equally. Off-axis sound may change in tone as well as level.

The frequency analyzer can help inspect spectral differences in supported input. Its spectrum alone cannot establish a microphone’s full polar response, because source spectrum, room reflections, placement and gain also affect the result.

Place the unwanted source deliberately

Identify where the desired sound arrives and where the unwanted sound arrives. For a directional microphone, orienting a weaker-response direction toward an avoidable source may help the relationship. With a rear-lobed pattern, simply placing the unwanted source directly behind may be ineffective.

Do not expect complete silence. A room reflects sound into several directions, and the direct path from a fan is only part of the acoustic field. The background noise test provides a separate timed observation, not a prediction of how every pattern will perform.

Distance and angle should be tracked separately

If you rotate the microphone and move it closer at the same time, the comparison combines two changes. If you then alter gain, a louder output may conceal whether the desired-to-background relationship improved.

For a useful experiment, keep the ordinary source position, distance and input settings fixed while changing one orientation. Repeat a short passage and compare the results. Then investigate distance as a separate variable if that is appropriate for the microphone and source.

Direct speech and room background

Bringing an appropriate microphone closer to speech can change the balance between the direct voice and more distant or reflected sound. Pattern and placement both matter; output sensitivity is another quantity and does not independently prove superior rejection.

The podcast room-noise guide explains placement in a recording workflow. The microphone versus room-noise comparison separates acoustic background from the electronics and gain that also contribute to the received signal.

Do not confuse pattern changes with changes in room SPL

If a directional microphone rotates and its displayed level changes, the room has not necessarily become louder or quieter. The measurement arrangement has changed. A result intended for comparison needs consistent geometry and an appropriate reference.

The homepage decibel meter online can support a separate level observation with its calibration limits. Read the microphone calibration guide before treating an adjusted reading as an accurate all-direction acoustic measurement.

Browser processing is not a physical polar-pattern switch

Software noise suppression, echo cancellation and automatic gain can change a received signal. They do not necessarily change the microphone capsule’s physical response. Some devices use arrays and additional processing, but that capability must be established for the specific device.

This site’s microphone test reports available input settings and uses the first captured channel for live analysis. It does not expose a universal cardioid-to-omni switch or assess every element of an array. Keep a device’s documented pattern selection separate from browser permission and processing controls.

Build a repeatable comparison

Record the model, selected hardware pattern, front orientation, source distance, approximate angle, room and input settings. Use the same ordinary passage rather than changing vocal effort to force a result. Listen for tone, desired sound and background together.

No microphone’s pattern was measured for this article. The model equation is illustrative, and the suggested recording procedure is a way to investigate your own setup, not a performance rating or a claim that one pattern is universally best.

Frequently asked questions

Does cardioid mean no sound from behind?

No. A real response is frequency- and model-dependent. An ideal diagram’s null should not be treated as guaranteed complete rejection in a room.

Is a condenser always omnidirectional?

No. Condenser describes a transducer principle, while a polar pattern describes directionality. Check the particular model and selected setting.

Is supercardioid always better than cardioid?

No. A narrower front response and rear lobe can create different placement requirements. Source movement and unwanted sound positions matter.

Does higher sensitivity mean more directional pickup?

No. Output sensitivity and directional response are separate specifications. A meaningful comparison must account for gain, angle and distance.

Can I identify the full pattern with one spectrum?

No. A full response assessment requires controlled angles, frequencies and conditions. One room recording mixes several influences.

Can a browser setting change my mic from cardioid to omni?

Not as a universal capability. Hardware pattern controls and array processing are device-specific; this site’s test does not supply that physical conversion.

Scroll to Top